Accueil
Catégories
Ajouter le résultat dans votre panier Affiner la recherche
Etendre la recherche sur niveau(x) vers le bas
[article]
Titre : AC and DC rue monitoring of composites Type de document : texte imprimé Auteurs : Huan Lee, Auteur ; Stephen Pomeroy, Auteur Année de publication : 2022 Article en page(s) : p. 48-51 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Composites
Contrôle non destructif
Mesures électriques
Réticulation (polymérisation)
ThermodurcissablesIndex. décimale : 668.4 Plastiques, vinyles Résumé : Both AC and DC techniques are currently used to study thermoset and composite cure. Understanding the characteristics of each is important for choosing a test method and avoiding misinterpretation of material state. The difference between AC and DC measurements is a critical distinction for companies in wind energy, automotive, aerospace and other industries that rely on cure monitoring to ensure the quality of advanced composite materials. Note de contenu : - Electric model of a thermoset resin
- Comparison : AC and DC cure monitoring
- Table 1 : Correspondance between thermoset and randles cell modelsEn ligne : https://drive.google.com/file/d/1Oyeson88om9eQffDVL5TCWcmYM1n44lY/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=38459
in JEC COMPOSITES MAGAZINE > N° 144 (01-02/2022) . - p. 48-51[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 23694 - Périodique Bibliothèque principale Documentaires Disponible Etude du polyallylbenzène et de ses dérivés polaires en tant que diélectriques / Gisèle Boiteux / 1981
Titre : Etude du polyallylbenzène et de ses dérivés polaires en tant que diélectriques Type de document : texte imprimé Auteurs : Gisèle Boiteux, Auteur ; Georges Vallet, Directeur de thèse ; Université Claude Bernard (Lyon), Organisme de soutenance Année de publication : 1981 Importance : 189 p. Présentation : ill. Format : 30 cm Note générale : Annexes - Bibliogr. Langues : Français (fre) Catégories : Analyse thermique
Analyse thermomécanique
Calorimétrie
Chloration
Chromatographie
Diélectriques
Dilatométrie
Mesures diélectriques
Mesures électriques
Nitration
Polyallylbenzène
Polymères -- Synthèse
Polymérisation
Thèses et écrits académiquesIndex. décimale : 668.9 Polymères Note de contenu : 1. SYNTHESE : Origine de la recherche - Bibliographie - Synthèses du polyallylbenzène - Modifications chimiques - Nitration
2. CARACTERISATION MOLECULAIRE ET STRUCTURALE : A. POLYALLYLBENZENE : Etude infrarouge - Etude de la diffraction des rayons X - Etude en microscopie optique - Etude en résonance magnétique nucléaire - B. POLYMERES MODIFIES : Polymères nitrés - Produits chlorés
3. COMPORTEMENTS THERMIQUES ET ELECTRIQUES : Analyse thermique différentielle - Analyse calorimétrique différentielle - 3. Dégradation thermique - Analyse thermomécanique - Dilatométrie - Chromatographie inverse en phase vapeur - Méthodes utilisées en mesures diélectriques - Mesures en courant alternatif basse fréquence - Mesures en courant continu - Thermocourants de dépolarisationThèse : Thèse. Université Claude Bernard - Lyon 1 : 1981 Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=1455 Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 0272 TH/1981/BOI Thèse, mémoire, etc... Bibliothèque principale Documentaires Disponible Health monitoring of CFRP using printed circuits / Till Augustin in JEC COMPOSITES MAGAZINE, N° 117 (11-12/2017)
[article]
Titre : Health monitoring of CFRP using printed circuits Type de document : texte imprimé Auteurs : Till Augustin, Auteur ; Bodo Fiedler, Auteur Année de publication : 2017 Article en page(s) : p. 61-63 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Composites à fibres de carbone
Conduction électrique
Détection de dommages (matériaux)
Encre
Flexion trois points
Mesures électriquesIndex. décimale : 668.4 Plastiques, vinyles Résumé : This study presents an approach for monitoring the structural health of CFRP using conductive paths of printed silver nanoparticule ink. Both delaminations and surface cracks can be detected by measuring the elctrical resistance during loading. Note de contenu : - Materials and specimen preparation
- Electrical resistance measurements along printed paths for surface crack detection
- Electrical measurements through the material for delamination detection
- FIGURES : 1. (a) Specimen geometry, design of conductive paths for measuring resistance along printed paths. (b) Three-point bending test setup with electrical resistance measurement along printed paths - 2. Force and resistance change of conductive paths versus displacement - 3. Light microscopy observation of printed paths after testing - 4. (a) Specimen geometry, design of conductive paths for measuring resistnace through the material. (b) Three-point beinding test setup with four-channel electrical resistance measurement through the material - 5. Force and resistance change of the four measured channels versus displacement - 6. Light microscopy observation of polished sections after testing. Region above electrode 2 and 3 (middle electrodes), inter-libre failures and delaminations and region above electrodes 1 and 4 (outer electrodes), only inter-fibre failuresEn ligne : https://drive.google.com/file/d/15cbhwk7tx4CZet_G4l3wV0MPb2He1bgx/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=29438
in JEC COMPOSITES MAGAZINE > N° 117 (11-12/2017) . - p. 61-63[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 19380 - Périodique Bibliothèque principale Documentaires Disponible Joining of contact pins and conductive compounds via injection molding - Influence of the flow situation on the electrical contact resistance / Hans-Peter Heim in INTERNATIONAL POLYMER PROCESSING, Vol. XXXV, N° 2 (05/2020)
[article]
Titre : Joining of contact pins and conductive compounds via injection molding - Influence of the flow situation on the electrical contact resistance Type de document : texte imprimé Auteurs : Hans-Peter Heim, Auteur ; F. Mieth, Auteur ; André Schlink, Auteur ; K. Wiegel, Auteur ; L. Brabetz, Auteur Année de publication : 2020 Article en page(s) : p. 184-192 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Assemblages (technologie)
Assemblages multimatériaux
Broches métalliques
Composites -- Moulage par injection
Composites -- Propriétés électriques
Conduction électrique
Cuivre
Graphite
Insert (technologie)En plasturgie ou fonderie, un insert désigne une pièce d'un matériau infusible incluse dans la pièce fabriquée. Cet élément sert en général à la fixation ultérieure d'éléments mécaniques ou sert de renfort (exemple : chemise d'usure).
Mesures électriques
Polypropylène
Résistance de contact électriqueIndex. décimale : 668.4 Plastiques, vinyles Résumé : While a lot of research can be found in the field of bulk resistance of carbon filled polymers, comparatively few papers focus on contact resistance between compound and metal contacts. Due to that small number of researches that deal with contact resistances, studies of the influence of injection molding conditions and parameters on the contact resistance are also very rare. In contradiction to that, these influences on bulk resistance have been studied. The objective of this work was to investigate the electrical contact resistance of overmolded tinplated copper contacts after modifying flow situations and molding conditions by procedural and constructional methods in contact areas. Metal pins were overmolded with a polypropylene compound containing 45 vol.% graphite, utilising an insert injection molding process. To affect the flow situation at the contacts, several processing parameters, such as mold temperature and injection speed, were modified. In addition, the contact alignment related to melt flow direction was varied. Electrical properties were studied and related to macroscopic and microscopic connection properties and flow situations in contact regions. It was found that the contact resistance is a significant factor while examining electrical resistances of overmolded samples. Furthermore, it was shown that the various flow situations had an essential impact on contact resistances. Weld lines at the position of the contact caused a decreased contact resistance. The correlation of the weld line effect, the filler orientation and contact resistance were successfully investigated by μ-CT. Regarding processing parameters, it was observed that a high mold temperature of 120 °C increased not only bulk conductivity, but also had a positive impact on contact conductivity. Macroscopic and microscopic connection mechanisms of contact surfaces were interpreted and connected to the experimental observations. Note de contenu : - Current status or research
- Materials
- Sample preparation
- Electrical measurements - Results
- Discussion : Macroscopic contact - Microscopic reproduction - Filler position within the interface - Connection of the filler particles close to the interfacesDOI : https://doi.org/10.3139/217.3879 En ligne : https://drive.google.com/file/d/19UY3Adlb4rpmXgeE9uXv5yEEUWG8Xsgf/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=34012
in INTERNATIONAL POLYMER PROCESSING > Vol. XXXV, N° 2 (05/2020) . - p. 184-192[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 21674 - Périodique Bibliothèque principale Documentaires Disponible Understanding effects of topical ingredients on electrical measurement of skin hydration / Jonathan M. Crowther in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 38, N° 6 (12/2016)
[article]
Titre : Understanding effects of topical ingredients on electrical measurement of skin hydration Type de document : texte imprimé Auteurs : Jonathan M. Crowther, Auteur Année de publication : 2016 Article en page(s) : p. 589-598 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Biotechnologie
Chimie analytique
Emulsions -- Emploi en cosmétologie
Formulation (génie chimique) -- Stabilité
Hydratation
Ingrédients cosmétiques
Mesure
Mesures électriques
Peau -- Soins et hygièneIndex. décimale : 668.5 Parfums et cosmétiques Résumé : Objectif : Les méthodes pour évaluer l'hydratation de la peau en fonction de ses propriétés électriques sont largement utilisées dans la recherche cosmétique et médicale. Toutefois, les appareils eux-mêmes donnent souvent des résultats qui sont significativement différents les uns des autres. Bien que certains travaux aient déjà été effectués pour essayer de comprendre ce que ces dispositifs enregistrent effectivement, ces études étaient basées sur une technique pour mesurer les réponses des dispositifs à l'aide de papier-filtre imprégné de différents liquides, ce qui pourrait influencer en lui-même les mesures. Ici est présentée une nouvelle méthode de mesure des réponses directes des appareils à différents matériaux et solutions qui supprime tous les autres effets interférants, offrant une vision plus claire de leur fonctionnement.
Méthodes : Les réponses des différents liquides et solutions ont été mesurées en utilisant le Cornéomètre® et le Skicon®. Une nouvelle méthode utilisant un bloc de PTFE conçu sur mesure pour contenir les liquides et permettant leur mesure sans l'aide d'un papier-filtre est présentée. Cette méthode a été développée et testée par rapport à l'approche actuelle basée sur les papier-filtre.
Résultats : Les résultats indiquent que le papier-filtre lui-même est capable d'influencer les mesures et ne doit donc pas être recommandé pour l'évaluation de la façon dont différents liquides influencent les résultats de ces appareils. Une corrélation positive a été observée entre les lectures au Cornéomètre® et au Skicon® pour certaines solutions. Une grande influence de la concentration en sel a été notée pour le dispositif Skicon®, ou avec un impact minimal ou nul de l'eau, des humectants ou émollients. Les sels, les émollients, l'eau et les humectants par contre modifient les lectures au Cornéomètre®.
Conclusion : Les deux appareils ont été influencés à des degrés divers par des produits chimiques autres que l'eau et leurs données ne peuvent donc pas être considérées uniquement comme des mesures de l'hydratation de la peau. Bien qu'il y ait des preuves solides que les dispositifs sont en corrélation avec l'évaluation d'experts de la sécheresse de la peau, le niveau de l'eau dans la peau est seulement une partie de l'histoire quand on cherche à comprendre les bénéfices des produits hydratants topiques. Une approche alternative serait de considérer “l'Hydratation” de la peau comme une propriété qui est influencée par l'eau, des sels et d'autres matériaux (humectants et émollients), ce qui est plus conforme à la façon dont la couche cornée elle-même contribue à maintenir sa plasticité et la flexibilité. Dans ce travail, le Cornéomètre® était plus adapté à fournir une mesure qui reflète l'impact de plusieurs composants différents.Note de contenu : - Study methodology outline
- Test materials
- Measurement techniquesDOI : 10.1111/ics.12324 En ligne : http://onlinelibrary.wiley.com/doi/10.1111/ics.12324 Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=27536
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 38, N° 6 (12/2016) . - p. 589-598[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 18479 - Périodique Bibliothèque principale Documentaires Disponible