Accueil
Catégories
Ajouter le résultat dans votre panier Affiner la recherche
Etendre la recherche sur niveau(x) vers le bas
An innovative nano-sorbent for selective solid-phase extraction and spectrophotometric determination of p-amino benzoic acid in cosmetic products / Hossein Abdolmohammad-Zadeh in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 36, N° 2 (04/2014)
[article]
Titre : An innovative nano-sorbent for selective solid-phase extraction and spectrophotometric determination of p-amino benzoic acid in cosmetic products Type de document : texte imprimé Auteurs : Hossein Abdolmohammad-Zadeh, Auteur ; S. Falaghi, Auteur ; E. Rahimpour, Auteur Année de publication : 2014 Article en page(s) : p. 140-147 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Aluminium L'aluminium est un élément chimique, de symbole Al et de numéro atomique 13. C’est un métal pauvre, malléable, de couleur argent, qui est remarquable pour sa résistance à l’oxydation13 et sa faible densité. C'est le métal le plus abondant de l'écorce terrestre et le troisième élément le plus abondant après l'oxygène et le silicium ; il représente en moyenne 8 % de la masse des matériaux de la surface solide de notre planète. L'aluminium est trop réactif pour exister à l'état natif dans le milieu naturel : on le trouve au contraire sous forme combinée dans plus de 270 minéraux différents, son minerai principal étant la bauxite, où il est présent sous forme d’oxyde hydraté dont on extrait l’alumine. Il peut aussi être extrait de la néphéline, de la leucite, de la sillimanite, de l'andalousite et de la muscovite.
L'aluminium métallique est très oxydable, mais est immédiatement passivé par une fine couche d'alumine Al2O3 imperméable de quelques micromètres d'épaisseur qui protège la masse métallique de la corrosion. On parle de protection cinétique, par opposition à une protection thermodynamique, car l’aluminium reste en tout état de cause très sensible à l'oxydation. Cette résistance à la corrosion et sa remarquable légèreté en ont fait un matériau très utilisé industriellement.
L'aluminium est un produit industriel important, sous forme pure ou alliée, notamment dans l'aéronautique, les transports et la construction. Sa nature réactive en fait également un catalyseur et un additif dans l'industrie chimique ; il est ainsi utilisé pour accroître la puissance explosive du nitrate d'ammonium.
Analyse spectrale
Chimie analytique
Extraction en phase solide
Hydroxydes doubles lamellaires
Hydroxydes métalliques
NickelLe nickel est un élément chimique, de symbole Ni et de numéro atomique 28.
Le nickel est un métal blanc argenté qui possède un éclat poli. Il fait partie du groupe du fer. C'est un métal ductile (malléable). On le trouve sous forme combinée au soufre dans la millérite, à l'arsenic dans la nickéline.
Grâce à sa résistance à l'oxydation et à la corrosion, il est utilisé dans les pièces de monnaie, pour le plaquage du fer, du cuivre, du laiton, dans certaines combinaisons chimiques et dans certains alliages. Il est ferromagnétique, et est fréquemment accompagné de cobalt. Il est particulièrement apprécié pour les alliages qu'il forme.
Parabènes
ZincIndex. décimale : 668.5 Parfums et cosmétiques Résumé : Objectif : Un nouveau nano-sorbant est développé pour l'extraction sélective et la pré- concentration de l'acide p-aminobenzoïque (PABA) avant sa détermination par spectrophotométrie.
Méthodes : L'extraction sélective de PABA à partir de solutions aqueuses a été effectuée en utilisant une colonne d'extraction en phase solide eremplie avec 200 mg de nickel - zinc-aluminium hydroxyde double lamellaire (Ni- Zn-Al LDH) en tant que nano-sorbant. La procédure d'extraction est basée sur l'adsorption d'ions à base de benzoate de p-amino sur le Ni- Zn-Al - LDH nitrate et/ou de leur échange avec les ions nitrate LDH intercalaires. Après l'élution de l'analyte extrait par 2.5 mL d'une solution 2 mol L−1 NaCl, sa concentration a été déterminée par spectrophotométrie à λmax = 268 nm.
Résultats : La méthode de spectrophotométrie a donné une réponse linéaire pour PABA dans la fourchette de 12.5 à 425.0 mg L−1 avec un coefficient de corrélation de 0.9994. Dans les conditions expérimentales optimales, la limite de détection et la capacité de sorption étaient 3.78 mg L−1 et 21.25 mg g−1, respectivement.
Conclusion : La méthode présentée utilise des conditions de séparation douce, et représente une technique sensible, reproductible, simple, peu coûteux et respectueux de l'environnement e qui pourrait être utilisée pour l'extraction et la détermination de PABA dans divers échantillons cosmétiques.Note de contenu : - MATERIALS AND METHODS : Apparatus and instruments - Standard solutions and reagents - Preparation of nickel-zinc-aluminium layered double hydroxide - Column preparation - Sample preparation - General procedure
- RESULTS AND DISCUSSION : Characterization of the nano-sorbent - Selection of layered double hydroxide - Optimization of solid-phase extraction conditions - Sorption capacity - Reusability of the nano-sorbent - Study of interferences - Analytical performance - Analysis of real samples - Comparison with other methodsDOI : 10.1111/ics.12107 En ligne : http://onlinelibrary.wiley.com/doi/10.1111/ics.12107 Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=21077
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 36, N° 2 (04/2014) . - p. 140-147[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 16179 - Périodique Bibliothèque principale Documentaires Disponible Characterization of the volatile organic compounds by HS-SPME-CG-MS in the leather sector / Rosa M. Cuadros in JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION (JALCA), Vol. CVIII, N° 11 (11/2013)
[article]
Titre : Characterization of the volatile organic compounds by HS-SPME-CG-MS in the leather sector Type de document : texte imprimé Auteurs : Rosa M. Cuadros, Auteur ; Agusti Marsal, Auteur ; Lluis Ollé, Auteur ; Anna Bacardit, Auteur ; Joaquim Font, Auteur Année de publication : 2013 Article en page(s) : p. 420-427 Note générale : Bibliogr. Langues : Américain (ame) Catégories : Caractérisation
Chromatographie en phase gazeuse
Cuir
Extraction en phase solide
Réduction des composés organiques volatils
Spectrométrie de masseIndex. décimale : 675 Technologie du cuir et de la fourrure Résumé : Current European legislation demands a reduction in the amount of volatile organic compounds (VOCs) used in industrial processes. The presence of these compounds in the leather industry arises from the chemicals used in the various stages of the leather manufacturing process. An important aim of tanners is to reduce or eliminate VOCs, without lowering the quality of their leather products. The HS-SPME-GC-MS method is an innovation in leather analysis. The solid phase micro extraction (SPME) is a sample preparation technique used for the extraction of volatile and semi-volatile organic compounds and is becoming widely accepted as the technique of choice for many applications and that can be connected to gas chromatography. The main advantages of this technique are speed, sensitivity, and the fact that it requires no sample handling or solvent extraction. Other advantages include the fact that the concentration and the extraction are reached simultaneously and that it enables on-site extraction of the analyte, even without the prior destruction of the sample. This paper shows the development of a new HS-SPME-GC-MS method with a deuterated internal standard for the detection and identification of volatile organic compounds emitted by leather. This method enables us to carry out a simple and rapid determination of the qualitative and semi-quantitative composition of the organic compounds in the samples. Note de contenu : - OBJECTIVE
- EXPERIMENTAL : Materials - Instrumentation - Samples - Procedure
- RESULTS AND DISCUSSION : Selection of the fiber - Limits of detection - Deuterated internal standard - Linearity - Recovery and precision - Analysis of commercial samples
- Table I : Values of ?area of the chromatograms of the four studied fibers
- Table II : Limite of detection and relative standard deviation (RSD) of VOCs
- Table III : Linearity and correlation coefficient of the four studied chemicals
- Table IV : Chemicals detected in commercial samplesEn ligne : https://drive.google.com/file/d/1Fozb01-dQmmasakLc3zDaDEzGjcQjh-f/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=19690
in JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION (JALCA) > Vol. CVIII, N° 11 (11/2013) . - p. 420-427[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 15707 - Périodique Bibliothèque principale Documentaires Disponible Determination of fungicides in residual tanning floats using solid phase micro extraction / Joaquim Font in JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION (JALCA), Vol. CVIII, N° 2 (02/2013)
[article]
Titre : Determination of fungicides in residual tanning floats using solid phase micro extraction Type de document : texte imprimé Auteurs : Joaquim Font, Auteur ; M. Reyes, Auteur ; Sara Cuadros, Auteur ; Anna Bacardit, Auteur ; Lluis Ollé, Auteur ; Agusti Marsal, Auteur Année de publication : 2013 Article en page(s) : p. 41-47 Note générale : Bibliogr. Langues : Américain (ame) Catégories : Adsorption
Antifongiques
Chromatographie en phase liquide à hautes performances
Cuirs et peaux -- Conservation
Désorption
DivinylbenzèneLe divinylbenzène (ou diéthénylbenzène en nomenclature systématique) est un hydrocarbure aromatique de formule C10H10. Comme son nom l'indique, il est constitué d'un noyau de benzène substitué par deux groupements vinyle (–CH=CH2). Il existe trois isomères du divinylbenzène, en fonction des positions relatives des groupements vinyle sur le noyau benzénique : 1. le 1,2-divinylbenzène ou orthodivinylbenzène, 2. le 1,3-divinylbenzène ou métadivinylbenzène, 3. le 1,4-divinylbenzène ou paradivinylbenzène.
PROPRIETES : Les composés ortho et méta sont à température et pression normales des liquides incolores, inflammables, irritant pour les muqueuses et se polymérisant facilement. Le composé para, dû à sa configuration particulière, a une température de fusion bien plus haute que les autres isomères (31 °C contre −67 °C pour les deux autres) et est donc solide à température ambiante. Ces trois composés sont insolubles dans l'eau.
UTILISATION : Les divinylbenzènes sont utilisés comme agent de réticulation dans des copolymères du polystyrène, ce qui réduit leur solubilité dans les solvants organiques, augmente leur résistance physique, leur dureté, leur résistance à la chaleur, sans affecter leur aspect et leurs propriétés optiques ou électriques.
Extraction en phase solide
PolydiméthylsiloxaneLe polydiméthylsiloxane —[O-Si(CH3)2]n—, ou poly(diméthylsiloxane) selon la nomenclature systématique, communément appelé PDMS ou diméthicone, est un polymère organominéral de la famille des siloxanes souvent présent dans les shampoings. On l'y ajoute pour augmenter le volume des cheveux mais il peut également aller boucher les pores du cuir chevelu et rendre les cheveux gras. C'est une des raisons pour lesquelles se laver les cheveux tous les jours est très déconseillé avec un shampooing contenant des silicones.
Il existe également de l'amodiméthicone, qui est un dérivé du diméthicone.
Le polydiméthylsiloxane est un additif alimentaire (E900), utilisé comme antimoussant dans les boissons (Coca-Cola BlāK).
La chaîne de poly(diméthylsiloxane) forme également la structure de base des huiles et des caoutchoucs silicones.Index. décimale : 675 Technologie du cuir et de la fourrure Résumé : Solid-phase microextraction (SPME) was optimized for extraction of the leather preservative agents 2-(thiocyanomethylthio)-benzothiazole (TCMTB), 4-chloro-3-methylphenol (PCMC), 2-phenylphenol (OPP), 2-Octyl-3(2H)-isothiazolone (OIT), 2-mercaptobenzothiazol (MBT) and 3-iodo-2-propynyl-butylcarbamate (IPBC) in spent tanning floats. Determination was carried out by high performance liquid chromatography (HPLC) with photo diode array detection (PDA). The following parameters were studied to achieve the maximum efficiency in extraction: fiber type, adsorption conditions (extraction time, ionic strength, temperature) and desorption parameters (time, temperature and composition of the desorption solvent). Results indicate that SPME using a 60µm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber is appropriate for the extraction of these types of compounds. Recoveries ranged from 82% to 116% with RSDs between ±8% and ±12% and limits of detection below 1 mg/L except for IPBC. The optimized procedure was successfully applied for the determination of leather preservatives in eleven residual tanning floats taken from different companies. This method enables us to determine quantitatively the fungicides contained in the residual floats. Consequently, it will constitute a very useful tool to improve the preservative uptake in leather manufacturing processes. Note de contenu : - EXPERIMENTAL : Materials - Instrumentation - Samples - Procedure
- RESULTS AND DISCUSSION : Fiber choice and development of desorption conditions - Adsorption conditions - Validation (linearity - Recovery and precision - Limits of detection and limits of quantification - Robustness of calibration) - Analyses of real samplesEn ligne : https://drive.google.com/file/d/1wku4fCcOK1qCDxOmZpiH6SqkzGjpSOCP/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=17368
in JOURNAL OF THE AMERICAN LEATHER CHEMISTS ASSOCIATION (JALCA) > Vol. CVIII, N° 2 (02/2013) . - p. 41-47[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 14610 - Périodique Bibliothèque principale Documentaires Disponible