Accueil
Catégories
Ajouter le résultat dans votre panier Affiner la recherche
Etendre la recherche sur niveau(x) vers le bas
A hairy situation : coating failure in a 10 000 gallon shampoo tank / Warren Brand in JOURNAL OF PROTECTIVE COATINGS & LININGS (JPCL), Vol. 33, N° 5 (05/2016)
[article]
Titre : A hairy situation : coating failure in a 10 000 gallon shampoo tank Type de document : texte imprimé Auteurs : Warren Brand, Auteur Année de publication : 2016 Article en page(s) : p. 20-26 Langues : Américain (ame) Catégories : Cosmétiques -- Appareils et matériels
Epoxydes
Expertises
Réservoirs (récipients) -- revêtements protecteurs
Revêtements -- Défauts
shampooingsIndex. décimale : 667.9 Revêtements et enduits Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=26836
in JOURNAL OF PROTECTIVE COATINGS & LININGS (JPCL) > Vol. 33, N° 5 (05/2016) . - p. 20-26[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 18124 - Périodique Bibliothèque principale Documentaires Disponible In vitro study into the SPF and UVA-PF using different applicators / Saul Pyle in IFSCC MAGAZINE, Vol. 16, N° 4 (10-11-12/2013)
[article]
Titre : In vitro study into the SPF and UVA-PF using different applicators Type de document : texte imprimé Auteurs : Saul Pyle, Auteur ; Dearbhaile Lynn, Auteur ; Don Ross, Auteur Année de publication : 2013 Article en page(s) : p. 255-261 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Cosmétiques -- Appareils et matériels
Cosmétiques -- Application-dosage
Etude in vitro
Etude in vivo
Facteur de protection solaire
Produits antisolaires
Rayonnement ultraviolet AIndex. décimale : 668.5 Parfums et cosmétiques Résumé : This report investigates the impacts of applicator materials on the in vitro SPF method and calculated UVA-PF following a method based on ISO 24443. The study found that the in vitro SPF varied considerably with changes to applicators. It was observed that particular characteristics of the applicators contributed to the measured SPF, where smooth textures that are often peculiar to particular materials generated the highest SPF and rough textures yielded a lower SPF. The potential mechanism behind the measured SPF was investigated and discussed including the potential implications on ISO 24444, which permits the use of applicators.
The calculated UVA-PF also varied with applicator and was observed to have an inverse relationship with the in vitro SPF, but the variability was far les pronounced and relatively erratic. Therefore, it was difficult to confirm the inverse relationship as absolute and further investigation may be necessary with a larger sample size allowing more detailed analysis that may highlight a more complicated trend.
While the reasoning behind the variation in UVA-PF is not well understood, a contributing factor relating the limits of detection at higher SPFs is visited, as observed on the 'adjusted normed mean curves' as found in the ISO 24443 spreadsheet, where the UVB aspect of the absorbance curve deviates from normality. The ramification of this deviation is then discussed, where it is noted that where the C value used to adjust the curve using the measured in vivo SPF is an indicator of reliability according to the recommended range (0.8 -1.6), it is not a dependable measure.Note de contenu : - EXPERIMENTAL : Equipment - Materials - Products - Applicator selection - Review - Analysis - Robustness and repeatability - Water resistance
- RESULTS AND DISCUSSION : Applicator analysis - Material and texture - Microscopic film evaluation - Adjusted normed mean - Robustness and repeatability - Water resistancePermalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=20159
in IFSCC MAGAZINE > Vol. 16, N° 4 (10-11-12/2013) . - p. 255-261[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 15845 - Périodique Bibliothèque principale Documentaires Disponible
[article]
Titre : Techniques for globally approved skin testing Type de document : texte imprimé Année de publication : 2013 Article en page(s) : p. 48-50 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Cosmétiques -- Appareils et matériels
Tests cutanésIndex. décimale : 668.5 Parfums et cosmétiques Résumé : In efficacy testing and claim support for cosmetic products, objective measurement systems became indispensable long ago, especially since subjective clinical assessments are often prone to bias and inter-observer variation. Note de contenu : - Skin measurments for claim support
- Working with skin testing in the laboratory : Measurement systems - Size and type of test group - Test conditions - Standardised measurements
- Others users of the instrumentationEn ligne : https://drive.google.com/file/d/1xMm8HFAbEUfjwoVOfaDKDHyq4U6Vt4HH/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=18204
in PERSONAL CARE EUROPE > Vol. 6, N° 2 (04/2013) . - p. 48-50[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 15016 - Périodique Bibliothèque principale Documentaires Disponible