Accueil
Catégories
Ajouter le résultat dans votre panier Affiner la recherche
Etendre la recherche sur niveau(x) vers le bas
An effective night slimming topical treatment / E. Berardesca in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 34, N° 3 (06/2012)
[article]
Titre : An effective night slimming topical treatment Type de document : texte imprimé Auteurs : E. Berardesca, Auteur ; E. Abril, Auteur ; C. Rona, Auteur ; R. Vesnaver, Auteur ; A. Cenni, Auteur ; M. Oliva, Auteur Année de publication : 2012 Article en page(s) : p. 263-272 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Amincissants
Echographie
Etude in vivo
Extraits de plantes:Extraits (pharmacie)Index. décimale : 668.5 Parfums et cosmétiques Résumé : The surface energy of the human nail plate is expected to influence the adhesion of microorganisms (and subsequent colonization and infections) as well as that of medicines (and subsequent drug permeation) and of cosmetics. The aim of the study was therefore to measure the surface energy of nail plates in vivo. The surface energy of healthy human fingernails (untreated, hydrated and abraded) and of hoof membranes (often used as a model for the nail plate) was estimated from contact angle measurements of liquids (water, formamide, diiodomethane and glycerol) on the nail plate and subsequent computation using the Lifshitz–van der Waals/acid–base (LW-AB) approach. The surface energy of untreated fingernail plates was found to be 34 mJ m−2. Most of this total energy was from the apolar Lifshitz–van der Waals component. When the polar component of the surface energy was analysed, the electron donor component was considerably larger than the electron acceptor one. Hydrating the nail plate had no significant influence on the surface energy. In contrast, abrasion caused a small, but statistically significant increase in the apolar surface energy component. The surface energy of bovine hoof membrane was similar to that of the fingernail plate. We conclude that the human fingernail plate is a low-energy surface and that bovine hoof membranes may be used as a substitute for the nail plate in certain experiments. Note de contenu : - Study design
- Study procedure
- Statistical analysis
- Statistical methodologyDOI : 10.1111/j.1468-2494.2012.00712.x En ligne : http://onlinelibrary.wiley.com/doi/10.1111/j.1468-2494.2012.00712.x Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=15037
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 34, N° 3 (06/2012) . - p. 263-272[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 13924 - Périodique Bibliothèque principale Documentaires Disponible Coatings choose ultrasound / Kurt Limbacher in POLYMERS PAINT COLOUR JOURNAL - PPCJ, Vol. 193, N° 4470 (11/2003)
[article]
Titre : Coatings choose ultrasound Type de document : texte imprimé Auteurs : Kurt Limbacher, Auteur Année de publication : 2003 Article en page(s) : p. 18-21 Langues : Anglais (eng) Catégories : Dépôt électrolytique
Dispersions et suspensions
Echographie
Emulsions
Epaississants
Homogénéisation (technologie)
Mélanges (chimie)
UltrasonsIndex. décimale : 667.9 Revêtements et enduits Résumé : The coatings industry is moving towards the use of ultrasound in its plants. The author explains how this innovative mixing technology works. Until fairly recently the use of ultrasonic energies in the production of emulsions and dispersions was cost prohibitive. But this has all changed with Sonolation, the development of mechanical generation of ultrasonic energy, which has made it easier to incorporate a sonic homogeniser into a coatings. Sonolation offers manufacturers opportunities for: increased plant investment with little capital investment, lower labour requirements and simplified processing techniques. Note de contenu : - Sonolation
- Application
- Good dispersion
- Electrocoating
- Emulsions and thickeners
- BenefitsPermalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=27812
in POLYMERS PAINT COLOUR JOURNAL - PPCJ > Vol. 193, N° 4470 (11/2003) . - p. 18-21[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 000307 - Périodique Bibliothèque principale Documentaires Disponible Getting the right tool for every application in INTERNATIONAL SURFACE TECHNOLOGY (IST), Vol. 12, N° 3 (2019)
[article]
Titre : Getting the right tool for every application Type de document : texte imprimé Année de publication : 2019 Article en page(s) : p. 42-44 Langues : Anglais (eng) Catégories : Courants de Foucault On appelle courants de Foucault les courants électriques créés dans une masse conductrice, soit par la variation au cours du temps d'un champ magnétique extérieur traversant ce milieu (le flux du champ à travers le milieu), soit par un déplacement de cette masse dans un champ magnétique. Ils sont une conséquence de l'induction électromagnétique.
Echographie
Epaisseur -- Mesure
Matériaux -- Epaisseur
Microscopie
Spectroscopie des rayons XIndex. décimale : 667.9 Revêtements et enduits Résumé : Coating thickness plays a large part in determining the quality and value of products and components. Find out more about the varied range of well-known, but also unexpected techniques that can be used to make industrial coating inspections faster, simpler and more precise. Note de contenu : - Microscopy
- Eddy current
- Ultrasound
- X-ray fluorescence
- Fig. 1 : Polished cross section of a plasma-coated sample. Low-magnification overview nd high-magnification image with measurement results of the two layers
- Fig. 2 : Eddy current flaw detectors use electricity and magnetism to measure the conductivity and thickness of a coating
- Fig. 3 : Ultrasonic scan from the Olympus 45MG thickness gage. The scan shows a metal component that has been coated with a corrosion-resistant alloy
- Fig. 4 : XRF spectra provide a fingerprint of the metals present in coatings - and give an indication of coating thickness
- Fig. 5 : Handheld XRF analyzers, can be used for inspection durig manufacturing as well as for in-service inspectionsEn ligne : https://drive.google.com/file/d/1UuEHMs4nIal-7pDvPb-IrVRsg359IZxW/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=33855
in INTERNATIONAL SURFACE TECHNOLOGY (IST) > Vol. 12, N° 3 (2019) . - p. 42-44[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 21131 - Périodique Bibliothèque principale Documentaires Disponible Structural changes in dermal collagen and oxidative stress levels in the skin of Japanese overweight males / M. Matsumoto in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 36, N° 5 (10/2014)
[article]
Titre : Structural changes in dermal collagen and oxidative stress levels in the skin of Japanese overweight males Type de document : texte imprimé Auteurs : M. Matsumoto, Auteur ; A. Ibuki, Auteur ; J. Sugama, Auteur ; M. Horii, Auteur ; K. Ogai, Auteur ; T. Nishizawa, Auteur ; M. Dai, Auteur ; A. Sato, Auteur ; Y. Fujimoto, Auteur ; M. Okuwa, Auteur ; G. Nakagami, Auteur ; T. Nakatani, Auteur ; H. Sanada, Auteur Année de publication : 2014 Article en page(s) : p. 477-484 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Collagène
Echographie
Japonais
Obésité
Peau masculine
Stress -- Effets physiologiques
Stress oxydatifIndex. décimale : 668.5 Parfums et cosmétiques Résumé : OBJECTIF : Il a été rapporté que les personnes obèses possèdent une structure mal organisée des fibres de collagène en raison de la dégradation du collagène dermique qui est provoquée par une augmentation du stress oxydatif associé à l'hypertrophie du tissu adipeux sous-cutané. Cependant, nous ne savons pas si une augmentation du stress oxydatif causée par l'accumulation de tissu adipeux sous-cutané et par une modification de la structure cutanée se produit également chez les personnes japonaises en surpoids et obèses. Les objectifs de cette étude sont d'identifier les changements structurels qui se produisent dans le derme et de mesurer les niveaux de stress oxydatif chez les hommes japonais en surpoids.
METHODES : Le groupe surpoids inclut 43 volontaires masculins japonais âgés entre 25 et 64 ans et d'un indice de masse corporelle (BMI/IMC) de ≥25 et <30. Le groupe témoin comprenait 47 hommes bénévoles âgés de 22 et 64 ans et ayant un IMC <25.
L'échographe DermaScan C à 20 MHz avec le logiciel pour analyses d'images a été utilisé. L'échogénicité du derme supérieur et inférieur a été mesurée. Le niveau d'expression de l'ARNm 1 (HMOX1) de l'hème oxygenase dans les follicules pileux a été analysé quantitativement par RT-PCR et a été utilisé comme marqueur du stress oxydatif. L'imagerie échographique et la collecte des follicules pileux ont été effectuées à la même place sur la cuisse, l'abdomen, et le bras.
RESULTATS : Le niveau d'expression de l'ARNm HMOX1 dans l'abdomen et dans la cuisse était significativement plus faible dans le groupe en surpoids que dans le groupe témoin. En outre, l'échogénicité de la partie supérieure du derme de l'abdomen et du derme inférieure de la cuisse et l'abdomen était significativement plus faible dans le groupe en surpoids que dans le groupe témoin.
CONCLUSION :Nous avons détecté une augmentation des niveaux de stress oxydatif et une diminution de la densité de collagène dermique sur le même site sur la cuisse, l'abdomen et le bras des hommes japonais en surpoids. Ces résultats suggèrent une fragilité du derme des hommes japonais en surpoids, ce qui pourrait avoir été causé par l'accumulation du tissu adipeux sous-cutané.Note de contenu : - MATERIALS AND METHODS : Study design and setting, Subjects - Measurements and instruments - Image analysis - Statistical analysis - Ethical considerations
- RESULTS : Demographics and characteristics of study population - Ultrasonographic imaging of dermis per body site - Evaluation of the skin parameters of the study participantsDOI : 10.1111/ics.12145 En ligne : http://onlinelibrary.wiley.com/doi/10.1111/ics.12145 Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=22007
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 36, N° 5 (10/2014) . - p. 477-484[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 16531 - Périodique Bibliothèque principale Documentaires Disponible