Accueil
Détail de l'auteur
Auteur V. Hondros |
Documents disponibles écrits par cet auteur
Ajouter le résultat dans votre panier Affiner la recherche
Analysis of the no-flow criterion based on accurate crystallization data for the simulation of injection molding of semi-crystalline thermoplastics / V. Hondros in INTERNATIONAL POLYMER PROCESSING, Vol. XXXIII, N° 3 (07/2018)
[article]
Titre : Analysis of the no-flow criterion based on accurate crystallization data for the simulation of injection molding of semi-crystalline thermoplastics Type de document : texte imprimé Auteurs : V. Hondros, Auteur ; M. Vincent, Auteur ; L. Freire ; Séverine A. E. Boyer ; Jean-Marc Haudin ; V. Royer ; G. François ; L. Ville Année de publication : 2018 Article en page(s) : p. 397-410 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Calorimétrie
Cristallisation
Polymères isotactiques
Polymères semi-cristallins
Polypropylène
Rhéologie
Simulation par ordinateur
Thermoplastiques -- Moulage par injection
ThermoplastiquesUne matière thermoplastique désigne une matière qui se ramollit (parfois on observe une fusion franche) d'une façon répétée lorsqu'elle est chauffée au-dessus d'une certaine température, mais qui, au-dessous, redevient dure. Une telle matière conservera donc toujours de manière réversible sa thermoplasticité initiale. Cette qualité rend le matériau thermoplastique potentiellement recyclable (après broyage). Cela implique que la matière ramollie ne soit pas thermiquement dégradée et que les contraintes mécaniques de cisaillement introduites par un procédé de mise en forme ne modifient pas la structure moléculaire.Index. décimale : 668.4 Plastiques, vinyles Résumé : It is well known in practice that the shape and dimensions of injected parts are highly dependent on the packing-holding stage. A major problem in semi-crystalline polymers is the prediction of the solidified layer, whose thickness has an important effect on shrinkage and warpage. We propose a pragmatic approach based on the concept of no-flow temperature. This temperature should be related to crystallization temperature, but the choice is not easy because it depends on cooling rate and pressure which are functions of time and position. The objective of the work is to evaluate the sensitivity of an injection molding computation to the no-flow temperature and to evaluate the relevance of its choice. The crystallization temperature of an isotactic polypropylene is determined as a function of cooling rate and pressure in laboratory experiments. The pressure dependence is measured using the original Cristapress cell. As a case study, we simulate the filling and post-filling of a plate mold using Rem3D, a 3D code for injection molding. Three no-flow temperatures and two sets of parameters for temperature dependence of viscosity are tested. Their respective influences on the pressure evolution are shown, and the crystallization temperature calculated a posteriori using the experimental material data is compared to the “arbitrary” no-flow temperature. Note de contenu : - EXPERIMENTAL : Material - Rheology - Differential Scanning Calorimetry (DSC) - High pressure cell
- EXPERIMENTAL RESULTS AND DISCUSSION : Rheology - Crystallization under atmospheric - Crystallization under pressure
- NUMERICAL SIMULATIONS : Presentation of Rem3D - Constitutive equations - Simulation of injection molding in a simple geometryDOI : 10.3139/217.3593 En ligne : https://www.degruyter.com/document/doi/10.3139/217.3593/pdf Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=30809
in INTERNATIONAL POLYMER PROCESSING > Vol. XXXIII, N° 3 (07/2018) . - p. 397-410[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 20044 - Périodique Bibliothèque principale Documentaires Disponible