Accueil
Détail de l'auteur
Auteur S.-E. Koch |
Documents disponibles écrits par cet auteur
Ajouter le résultat dans votre panier Affiner la recherche
Statistical reference figures related to biocide concentrations in leathers and reflection on correlation concerning material loads and emission findings based on test chamber evaluation / J. Galinkina in JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS & CHEMISTS (JSLTC), Vol. 104, N° 4 (07-08/2020)
[article]
Titre : Statistical reference figures related to biocide concentrations in leathers and reflection on correlation concerning material loads and emission findings based on test chamber evaluation Type de document : texte imprimé Auteurs : J. Galinkina, Auteur ; S.-E. Koch, Auteur ; G. Frank, Auteur ; D. Singer, Auteur ; C. Schelle, Auteur Année de publication : 2020 Article en page(s) : p. 170-183 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Antimicrobiens
Concentration minimale inhibitrice (antimicrobiens)En microbiologie, la concentration minimale inhibitrice (CMI) est la plus faible concentration d'un produit chimique, généralement un médicament, qui empêche la croissance visible d'une ou de plusieurs bactéries. La CMI dépend du micro-organisme considéré, de l'être humain affecté (in vivo uniquement) et de l'antibiotique lui-même.
La CMI est déterminée en préparant des solutions du produit chimique in vitro à diverses concentrations croissantes, en incubant les solutions avec des groupes séparés de bactéries en culture et en mesurant les résultats en utilisant une méthode de dilution standardisée (agar ou microdilution). Les résultats se classent ensuite comme "sensible", "intermédiaire" ou "résistant" à un antimicrobien particulier en utilisant un point d'arrêt. Les points d'arrêt sont des valeurs convenues, publiées dans les directives d'un organisme de référence, comme le US Clinical and Laboratory Standards Institute (CLSI), la British Society for Antimicrobial Chemotherapy (BSAC) ou le Comité européen sur les tests de sensibilité aux antimicrobiens (EUCAST). On a pu constater des écarts importants au niveau des points d'arrêt de divers pays européens au fil des ans, et entre ceux de l'EUCAST et du CLSI.
Alors que la CMI est la concentration la plus faible d'un agent antibactérien nécessaire pour inhiber la croissance visible, la concentration bactéricide minimale (CBM) est la concentration minimale d'un agent antibactérien qui entraîne la mort bactérienne. Plus la CMI est proche de la CBM, plus le composé est bactéricide.
La première étape de la découverte d'un médicament est souvent le dépistage d'un médicament candidat de banque de données pour les CMI contre les bactéries d'intérêt. En tant que tels, les CMI sont généralement le point de départ pour de plus grandes évaluations précliniques de nouveaux agents antimicrobiens. Le but de la mesure de la concentration minimale inhibitrice est de s'assurer que les antibiotiques sont choisis efficacement pour augmenter le succès du traitement. (Wikipedia)
Cuirs et peaux -- Analyse
Cuirs et peaux -- Teneurs en antimicrobiens
Essais (technologie)
StatistiqueIndex. décimale : 675 Technologie du cuir et de la fourrure Résumé : Both application and usage of biocides and preservatives are legally regulated within the European Union. In that sense, the active agents used in products have to undergo an approval procedure. This approach shall ensure that exclusively biocidal products are marketed which bear no negative effects for human beings in the scope of preventive consumer protection and the environment. In tradition, within the leather manufacturing process biocidal acting substances are used at different production steps regarding the chain of custody. Especially in the field of raw hides' transport and storage and in semi-finished tanning stages ('wet-white' and 'wet-blue') characterised by high humidity content, biocidal agents are prophylactically utilised as constitutional ingredients to minimise the burden of adversely acting micro-organisms and for product valuable feature maintenance. As means of quality assessment and leather labelling different evaluation programs are available in the test market. On the one hand, these evaluation schemes focus on compliance with defined material based maximum concentrations in the leather matrix for selected and accepted biocides. On the other hand, quantifiable biocidal concentrations are limited with regard to their test chamber concentrations. In the scope of this work available datasets referring to a collective of examined leather types have been statistically evaluated, and a reflection on correlation between biocidal material contents and test chamber concentrations was made evaluating the current state of the art technology. Note de contenu : - PRESERVATIVES AND BIOCIDAL ACTING AGENTS : Selection of concerned agents - Mode of micro-biocidal action and minimum inhibition concentrations (MIC)
Mode of micro-biocidal action and minimum inhibition concentrations (MIC)
- MATERIAL ANALYSES AND TEST CHAMBER EXAMINATIONS : HPLC analytical aspects for determination of TCMTB and its metabolites (MBT, MBTS)
- TEST SAMPLES
- STATISTICS : Bagatelle biocide concentration threshold (BBCT)
- EVALUATION RESULTS : Frequency rates of biocide materials concentrations - Frequency distributions of biocide combinations - Material concentration interval clustered frequency scales - 4-Chloro-m-cresol (PCMC) - (Benzothiazol-2-ylthio)methyl thiocyanate (2-Thiocyanomethylthiobenzothiazol, TCMTB) - Biphenyl-2-ol(o-phenylphenol, OPP) - 2-Octyl-2H-isothiazol-3-one (n-Octylisothiazolinone, NOIT
- REFLECTION ON CORRELATION BETWEEN BIOCIDE MATERIAL AND TEST CHAMBER QUANTIFIED EMISSION CONCENTRATIONS : Available test scheme related maximum material and permissible test chamber concentrations - GC-/MS-analytical NOIT and TCMTB aspects - PCMC emission concentrations (CTC/PCMC) subject to quantified material content (MAT/PCMC) - OPP emission concentrations (Ctc/opp) subject to quantified material content (CMAT/OPP) - Benzothiazole emission concentrations (CTC/BT) subject to quantified TCMTB material content (CMAT/CMTB)
- INTERPRETATIONS OF RESULTS AND FORECAST : Discussion on modification of test scheme related material content maximum concentration limits I and II for PCMC, OPP and NOIT - trest chamber correlating concentrations versus permissible reduced biocide material content mass concentrations
En ligne : https://drive.google.com/file/d/1F-nSOieTH8xtRSWZsXIKAMqOM2Y81vAq/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=34330
in JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS & CHEMISTS (JSLTC) > Vol. 104, N° 4 (07-08/2020) . - p. 170-183[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 21881 - Périodique Bibliothèque principale Documentaires Disponible Test chamber-based VOC quantification results of upholstery leathers focused on statistical frequency scales for TVOC and single compound concentrations / G. Frank in JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS & CHEMISTS (JSLTC), Vol. 100, N° 5 (09-10/2016)
[article]
Titre : Test chamber-based VOC quantification results of upholstery leathers focused on statistical frequency scales for TVOC and single compound concentrations Type de document : texte imprimé Auteurs : G. Frank, Auteur ; S.-E. Koch, Auteur ; D. Singer, Auteur ; C. Schelle, Auteur Année de publication : 2016 Article en page(s) : p. 225-237 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Air intérieur -- Analyse
Air intérieur -- Pollution
Composés organiques volatils
Cuir d'ameublementIndex. décimale : 675 Technologie du cuir et de la fourrure Résumé : In the scope of upholstery leather emission evaluation various test specifications on the basis of test chamber examinations are implemented requiring an ambient air concentration hygienic assessment after 3 and 28 days conditioning periods. The quantified VOC test chamber concentrations are compared with defined target values. With increasing frequency, tanneries and the leather processing industry force test institutes into the approach to generate valid ratings of potential contaminant loads by applying short-terra evaluations.
Both the arrangement of an expressive pool of measured data on upholstery leathers and proficiency of measuring time-point related VOC frequency scales and their reciprocal dependences (interdependency) should enable an estimation approach : On the basis of quantified TVOC (Total VOC) and single compound concentrations measured at time-point t1 = 3d a prediction on a derivable probability can be drawn to which extent leather samples may comply with the threshold limits defined for the prolonged evaluation reading point t2 = 28d. From the aspect of a statistical data arrangement, this article summarizes upholstery leather samples VOC test results including discussion of approaches for usage of VOC results extracted from short-term evaluations.Note de contenu : - EVALUATION SCHEMES AND GUIDE VALUE THRESHOLD LIMITS : Test collection and sample size - Concentrations of volatile (VOC) and semi-volatile organic compounds - Discussion of quantification time-point related TVOC frequency scales - Evaluation of time-point related dependences of TVOC/TSVOC frequency cumulations
- DISCUSSION OF THE INTERDEPENDENCE
- STATISTICAL ARITHMETIC MEAN AS A REFLECTION OF TIME-DEPENDENT INDIVIDUAL SUBSTANCE CONCENTRATIONS : Time-dependent concentration course of 1,2-propandiol - Characteristics of the time-dependent concentration gradient of 1,2-propandiol - Time-dependent concentration behaviour of dipropylene glycol monomethylether (DPGMME) - Characteristic of the time-dependent concentration gradient of DPGMME - Time-dependent concentration behaviour of N-ethyl-2-pyrrolidone - Characteristic of the time-dependent concentration gradient of N-ethyl-2-pyrrolidone - Time-dependent concentration behaviour of ?-propylene glycol monomethyl ether - Characteristic of the time-dependent concentration gradient of ?-propylene glycol monomethyl ether
- SHORT-TERM TEST CHAMBER EMISSION TESTS : Assessment of CTVOC28d guide threshold limit compliance feasibility based on a short-term emission testEn ligne : https://drive.google.com/file/d/1OGCs3HoL6uLWoy6dxXLz6tDXiOUo69Zl/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=27082
in JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS & CHEMISTS (JSLTC) > Vol. 100, N° 5 (09-10/2016) . - p. 225-237[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 18411 - Périodique Bibliothèque principale Documentaires Disponible