Accueil
Catégories
Ajouter le résultat dans votre panier Affiner la recherche
Etendre la recherche sur niveau(x) vers le bas
Analysis of an unsteady quasi-capillary channel flow with time-resolved PIV and RBF-based super-resolution in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, Vol. 20, N° 1 (01/2023)
[article]
Titre : Analysis of an unsteady quasi-capillary channel flow with time-resolved PIV and RBF-based super-resolution Type de document : texte imprimé Année de publication : 2023 Article en page(s) : p. Note générale : Bibliogr. Langues : Américain (ame) Catégories : Angle de contact
Ecoulement capillaire
Interfaces solide-liquide
Mesure
Modèles mathématiques
Mouillage (chimie des surfaces)Tags : 'Canal quasi capillaire instable' 'PIV résolu en temps' 'Super résolution RBF' 'Angles de contact dynamiques' 'Mouillage dynamique' Index. décimale : 667.9 Revêtements et enduits Résumé : We investigate the interface dynamics in an unsteady quasi-capillary channel flow. The configuration consists of a liquid column that moves along a vertical 2D channel, open to the atmosphere and driven by a controlled pressure head. Both advancing and receding contact lines were analyzed to test the validity of classic models for dynamic wetting and to study the flow field near the interface. The operating conditions are characterized by a large acceleration, thus dominated by inertia. The shape of the moving meniscus was retrieved using Laser-Induced Fluorescence-based image processing, while the flow field near was analyzed via Time-Resolved Particle Image Velocimetry (TR-PIV). The TR-PIV measurements were enhanced in the post-processing, using a combination of Proper Orthogonal Decomposition and Radial Basis Functions to achieve super-resolution of the velocity field. Large counter-rotating vortices were observed, and their evolution was monitored in terms of the maximum intensity of the Q-field. The results show that classic contact angle models based on interface velocity cannot describe the evolution of the contact angle at a macroscopic scale. Moreover, the impact of the interface dynamics on the flow field is considerable and extends to several capillary lengths below the interface. Note de contenu : - EXPERIMENTAL SETUP AND TEST CASES : Modeling and parameter definition - Experimental conditions and test cases
- MEASUREMENT TECHNIQUES : LIF visualization : setup and processing - TR-PIV : setup - Super-resolution of PIV fields
- RESULTS : LIF visualization results - TR-PIV experiment results
- Table 1 : Experiments in the LIF-based visualization
- Table 2 : Experiments in the TR-PIV campaignDOI : https://doi.org/10.1007/s11998-022-00664-4 En ligne : https://link.springer.com/content/pdf/10.1007/s11998-022-00664-4.pdf?pdf=button% [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=38827
in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH > Vol. 20, N° 1 (01/2023) . - p.[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 23928 - Périodique Bibliothèque principale Documentaires Disponible
[article]
Titre : Breaking the ice : The innovative world of icephobic coatings Type de document : texte imprimé Auteurs : Cynthia A. Gosselin, Auteur Année de publication : 2024 Article en page(s) : p. 38-41 Note générale : Bibliogr. Langues : Américain (ame) Catégories : Glaciophobie
Hydrophobie
Interfaces (Sciences physiques)
Interfaces liquide-liquide
Interfaces solide-liquide
Revêtements antigelIndex. décimale : 667.9 Revêtements et enduits Résumé : Anyone who has had the pleasure of scraping ice off a car windshield, looking nervously at beautiful but deadly ice spears hanging from winter rooftops, or waiting on a slow and interminably long aircraft deicing line at an airport has dreamed of having some sort of coating that would eliminate inconvenient ice and snow accumulation. The desire to triumph over ice and snow accumulation has, in fact, been the focus of significant technical work that has been going on since the 1940s in an attempt to make all kinds of surfaces iceand snowphobic.
Icephobicity is defined as the ability of a solid surface to repel ice or prevent ice-film formation due to topographical structures at the ice-surface interface. Ice-repelling characteristics are attributed to the surface structure (sometimes called surface roughness) and/or low surface energy leading to poor ice adhesion allowing for easy removal.Note de contenu : - Fig. 1 : Hydrophobicity as defined by liquid contact angle
- Fig. 2 : Schematic of a superhydrophobic surface
- Fig. 3 : Ice adhesion depends upon the detachment mode, deformability in shear mode, and hydrophobicity in tensile mode
- Fig. 4 : Schematic illustrating water droplet behavior on surfaces with and without a magnetic field applied. The water droplet on the MAGSS surface forms a magnetic liquid-water interface with lower interfacial strength than solid/water interfaces
- Fig. 5 : A) Water allowed to freeze on an uncoated copper plate is difficult to remove–even after scraping. (B) Placing a magnet beneath the copper plate and coating the top with ferrofluid delayed water freezing and reduced the ice/surface interfacial strength to the point that ice was easily removed from the surface (or slid off if the panel was tilted even 2.5°)En ligne : https://drive.google.com/file/d/1VXqHT0gHatjPzSHPw82ls8pf2VNWjwZC/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=40428
in COATINGS TECH > Vol. 21, N° 1 (01-02/2024) . - p. 38-41[article]Exemplaires
Code-barres Cote Support Localisation Section Disponibilité aucun exemplaire Evaluation of thermal contact resistance of molten resin–mold interface during high-thermal-conductivity polyphenylene sulfide filling in injection molding / Akifumi Kurita in INTERNATIONAL POLYMER PROCESSING, Vol. 39, N° 2 (2024)
[article]
Titre : Evaluation of thermal contact resistance of molten resin–mold interface during high-thermal-conductivity polyphenylene sulfide filling in injection molding Type de document : texte imprimé Auteurs : Akifumi Kurita, Auteur ; Yohei Yoshimura, Auteur ; Makoto Suzuki, Auteur ; Hidetoshi Yokoi, Auteur ; Yusuke Kajihara, Auteur Année de publication : 2024 Article en page(s) : p. 242-259 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Interfaces (Sciences physiques)
Interfaces solide-liquide
Matières plastiques -- Moulage par injection
Polysulfures de phénylène
ThermocinétiqueIndex. décimale : 668.4 Plastiques, vinyles Résumé : High-thermal-conductivity polyphenylene sulfide (PPS) has both mechanical and heat dissipation properties, and its low weight and fuel efficiency make it a suitable replacement for metals in automobiles. However, this resin often causes filling defects in the injection molding process. This is due to the higher thermal conductivity, which causes the molten resin to solidify more quickly during the filling process. Therefore, it is important to predict the cooling and filling behaviors of the resin accurately using computer-aided engineering (CAE). Currently, many commercial software programs use thermal contact resistance (TCR) as the thermal boundary condition between the mold and resin. However, there is no established method to accurately evaluate TCR during filling with high spatial resolution and response, and the accuracy of CAE cannot be maintained. Therefore, we used thermography and a prismatic glass insert mold to thermally visualize and analyze the filling process of this resin. Consequently, we succeeded in evaluating TCR values with high spatial resolution and response. The obtained TCR values varied depending on the flow state and pressure. To further validate the obtained TCR values, we compared “the visualization results of real flow conditions” and “the flow prediction results of CAE considering the obtained TCR values”. Note de contenu : - MATHEMATICAL MODEL OF HEAT TRANSFER AND TCR EVALUATION METHOD
- EXPERIMENTAL METHOD : Experimental method - In-process temperature distribution visualization system - Cavity shape, material, and molding conditions in TCR measurement experiments - Simulation of TCR measurements
- EXPERIMENTAL RESULTS AND DISCUSSION OF TCR MEASUREMENT : Simulation results of TCR measurements - Visualization analysis of temperature distribution and evaluation results of TCR
- VISUALIZATION ANALYSISI AND CAE OF FILLING BEHABIOR : Cavity shape, material, and molding conditions for partial thin-walled filling behavior tests - Results and discussion of visualization analysis of filling behavior of high-thermal-conductivity PPS - Results and discussion of CAE prediction of filling behaviour
- SUMMARY AND FUTURE SCOPE
- APPENDIX A : PHYSICAL PROPERTIES OF RESINS USED IN CAEDOI : https://doi.org/10.1515/ipp-2023-4448 En ligne : https://drive.google.com/file/d/152EnzAiJiBqS1C4mB_b7zhUBwk61AQrD/view?usp=drive [...] Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=40867
in INTERNATIONAL POLYMER PROCESSING > Vol. 39, N° 2 (2024) . - p. 242-259[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 24725 - Périodique Bibliothèque principale Documentaires Disponible Glissement d'un fondu enchevêtré sur une surface greffée / Armand Ajdari in LES CAHIERS DE RHEOLOGIE, Vol. XI, N° 3-4 (10/1993)
[article]
Titre : Glissement d'un fondu enchevêtré sur une surface greffée Type de document : texte imprimé Auteurs : Armand Ajdari, Auteur Année de publication : 1993 Article en page(s) : p. 381-392 Note générale : Bibliogr. Langues : Français (fre) Catégories : Ecoulement instationnaire (dynamique des fluides)
Etat fondu (matériaux)
Fluides, Mécanique des
Interfaces solide-liquide
Polymères
RhéologieIndex. décimale : 668.9 Polymères Résumé : La présence ou non de glissement lorsqu'une solution ou un fondu de polymères s'écoule le long d'une surface est une question d'importance pour de nombreuses applications (lubrification, extrusion...).
Ainsi, parmi les nombreux éléments supposés expliquer les phénomènes d'instabilité lors de l'extrusion d'un polymère fondu on retrouve essentiellement la compressibilité finie du fondu et la présence de rupture cohésive (glissement le long d'une surface au sein du fondu) et adhésive (glissement à l'interface paroi/fondu).
Si de nombreuses approches macroscopiques ont récemment permis d'appréhender la variété et la complexité des effets observés, une tâche parallèle est le développement de modèles moléculaires justifiant les lois et paramètres phénoménologiques utilisés à plus grande échelle. Nous proposons ici quelques éléments de description du phénomène de glissement à l'interface solide/fondu enchevêtré dans le cas ou accidentellement ou non, des chaines sont greffées à la surface.Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=5848
in LES CAHIERS DE RHEOLOGIE > Vol. XI, N° 3-4 (10/1993) . - p. 381-392[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 002104 - Périodique Bibliothèque principale Documentaires Disponible Identification des contraintes de rupture et de cisaillement à l'interface polymère injecté/moule métallique à l'aide du test couronne / M. Guichon in MATERIAUX & TECHNIQUES, Vol. 96, N° 1/2 (2008)
[article]
Titre : Identification des contraintes de rupture et de cisaillement à l'interface polymère injecté/moule métallique à l'aide du test couronne Type de document : texte imprimé Auteurs : M. Guichon, Auteur ; C. Boher, Auteur ; B. Hassoune-Rhabbour, Auteur Année de publication : 2008 Article en page(s) : p. 65-77 Note générale : Bibliogr. Langues : Français (fre) Catégories : Cisaillement (mécanique)
Interfaces solide-liquide
Matières plastiques -- Moulage par injection
Polymères -- RuptureTags : Test couronne Résumé : Durant le procédé de moulage par injection, le polymère entrant en contact avec la paroi suit l'effet Fontaine. Cet effet consiste en la formation très rapide d'une gaine froide adhérente à la paroi (les conditions de contact passent d'un polymère fondu sur une paroi solide à un contact semi-solide/solide). Le défaut de vague est analysé. Ce défaut est crée à cause d'une instabilité au front de matière. Une des hypothèses de formation de cet écoulement particulier est le glissement à la paroi lors de la phase de remplissage [L. Mathieu et al. Int.Process XVI-4 (2001) 404-411 ; B. Monasse et al. 15th Annual meeting of the PPS, Hertogenbosh, Netherlands, 1999 ; S.Y. Hobbs; Poly. Eng. Sci. 32 (1996) 1489-1494 ; M.C.O. Chang. Int. poly. Process. XI-4 (1997) 403-411]. Afin de vérifier cette hypothèse, nous avons réalisé un modèle numérique sou le logiciel FORGE2, qui grâce à des conditions aux limites dissymétriques particulières (contact collant à contact glissant), recrée cet écoulement instable [M. Guichon et al., A study of polymer/mold contact during injection molding, regional PPS-2005, Quebec City]. La contrainte à la paroi se révèle être un bon critère afin de vérifier si le polymère peut glisser lors de la phase de remplissage. Dans ce but, nous avons utilisé un test de rupture appelé test couronne développé par B. Hassoune-Rhabbour et al. [7th European Adhesion Conference - EURADH 2004, september 5-9, 2004, Freiburg/Germany]. Celui-ci permet d'obtenir des valeurs de contraintes lors de la séparation d'une couronne de polymère solide (injectée) autour d'un cylindre en aluminium. Les valeurs de contraintes de rupture interfaciales obtenues avec ce test, ainsi que les valeurs des contraintes de cisaillement à l'interface polymère/substrat, nous permettront, par analogie, de comprendre et de caractériser les mécanismes mis en jeu lors du détachement éventuel de la gaine froide lors de l'écoulement de la phase de remplissage. DOI : http://dx.doi.org/10.1051/mattech:2008024 En ligne : http://www.mattech-journal.org/articles/mattech/pdf/2008/01/mt06064.pdf Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=2379
in MATERIAUX & TECHNIQUES > Vol. 96, N° 1/2 (2008) . - p. 65-77[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 010698 - Périodique Bibliothèque principale Documentaires Disponible Influence of additives on interfacial phenomena during film formation of powder coatings / Petra Uhlmann in JOURNAL OF COATINGS TECHNOLOGY (JCT), Vol. 73, N° 915 (04/2001)
PermalinkLes interfaces métal/eau : un défi pour la modélisation / Paul Clabaut in L'ACTUALITE CHIMIQUE, N° 465 (09/2021)
PermalinkLowering the tension / Vicky James in POLYMERS PAINT COLOUR JOURNAL - PPCJ, Vol. 197, N° 4510 (03/2007)
PermalinkLa microscopie électrochimique à balayage / Philippe Hapiot in L'ACTUALITE CHIMIQUE, N° 327-328 (02-03/2009)
PermalinkModélisation et simulation numérique de l’étalement goutte fluide sur un plan horizontal / H. Alla in RHEOLOGIE, Vol. 6 (10/2004)
PermalinkObservation of sessile droplet freezing on textured micropillar surfaces via visualization and thermography / Yuan Wang in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, Vol. 16, N° 3 (05/2019)
PermalinkPaint/polymer interface structure for ABS injection moldings / Y. Aoki in INTERNATIONAL POLYMER PROCESSING, Vol. XXVI, N° 4 (09/2011)
PermalinkPhysico-chimie des interfaces chargées / Benjamin Rotenberg in L'ACTUALITE CHIMIQUE, N° 384 (/04/2014)
PermalinkPressure variation during interfacial instability in the coextrusion of low density polyethylene melts / Mike T. Martyn in INTERNATIONAL POLYMER PROCESSING, Vol. XXVIII, N° 5 (11/2013)
PermalinkThe reduction in ice adhesion using controlled topography superhydrophobic coatings / Yujie Wang in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, Vol. 20, N° 2 (03/2023)
PermalinkTransition de glissement à l'interface polymère/solide / K. B. Migler in LES CAHIERS DE RHEOLOGIE, Vol. XI, N° 3-4 (10/1993)
Permalink