Accueil
Détail de l'auteur
Auteur B. Kapalavavi |
Documents disponibles écrits par cet auteur
Ajouter le résultat dans votre panier Affiner la recherche
Industrial application of green chromatography – II. Separation and analysis of preservatives in skincare products using subcritical water chromatography / Y. Yang in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 34, N° 5 (10/2012)
[article]
Titre : Industrial application of green chromatography – II. Separation and analysis of preservatives in skincare products using subcritical water chromatography Type de document : texte imprimé Auteurs : Y. Yang, Auteur ; B. Kapalavavi, Auteur ; L. Gujjar, Auteur ; S. Hadrous, Auteur ; R. Marple, Auteur ; C. J. Gamsky, Auteur Année de publication : 2012 Article en page(s) : p. 466-476 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Analyse quantitative (chimie)
Chromatographie à l'eau subcritique
Chromatographie liquide à haute température
Conservateurs (chimie)
Cosmétiques
Cosmétiques -- Analyse
Parabènes
Séparation (technologie)Tags : 'Alcool benzyl' 'Butyl paraben' 'Ethyl 'Méthyl 'Propyl 'Chromatographie liquide haute température' 'Application industrielle' 'Conservateurs cosmétiques' Quantification 'Crême soin' eau subcritique' 'XBridge C18' phenyl' ZirChrom-DiamondBond-C18 ZirChrom-PS Index. décimale : 668.5 Parfums et cosmétiques Résumé : Plusieurs méthodes de chromatographie liquide à haute température (HTLC) et de chromatographie à eau sous-critique (SBWC) ont été développées avec succès dans cette étude pour la séparation et l'analyse des conservateurs contenus dans les crèmes de soin Olayâ„¢. Une séparation efficace et un dosage des agents conservateurs ont été réalisés sur quatre colonnes ZirChrom et Watersâ„¢ Xbridge, disponibles dans le commerce, à des températures allant de 100 à 200°C. Les résultats de quantification obtenus par ces méthodes à la fois HTLC et SBWC, développées pour l'analyse des agents conservateurs sont précis et reproductibles. Un grand nombre de répétitions d'analyses SBWC et HTLC indique également l'absence d'accumulations ou d'interférences dans l'analyse des crèmes de soin. Par rapport à la séparation traditionnelle CLHP réalisée à température ambiante, la méthode de chromatographie liquide à haute température permet d'économiser jusqu'à 90% du méthanol nécessaire dans la phase mobile CLHP. Toutefois, les méthodes de chromatographie à eau subcritique développées dans ce projet éliminent complètement la nécessité de l'utilisation de solvants organiques toxiques nécessaires dans la phase mobile CLHP, ce qui permet d'économiser une quantité importante d'argent et de rendre l'environnement plus vert. Bien que les deux systèmes "maison" et ceux disponibles dans le commerce peuvent réaliser des séparations SBWC, les méthodes SBWC utilisant les systèmes commerciaux pour l'analyse des conservateurs sont recommandés pour les applications industrielles, car ils peuvent être directement appliquées dans ces contextes. Note de contenu : - MATERIALS AND METHODS : Reagents and materials - Separation columns - Preparation of solutions - SBWC/HTLC system and its operation
- RESULTS : ZirChrom-DiamondBond-C18 column - ZirChrom-PS column - Waters XBridge C18 column - Waters Xbridge phenyl columnDOI : 10.1111/j.1468-2494.2012.00738.x En ligne : http://onlinelibrary.wiley.com/doi/10.1111/j.1468-2494.2012.00738.x Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=16578
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 34, N° 5 (10/2012) . - p. 466-476[article]Réservation
Réserver ce document
Exemplaires (2)
Code-barres Cote Support Localisation Section Disponibilité 14347 - Périodique Bibliothèque principale Documentaires Disponible 15779 - Périodique Bibliothèque principale Documentaires Disponible Separation of sunscreens in skincare creams using greener high-temperature liquid chromatography and subcritical water chromatography / B. Kapalavavi in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 34, N° 2 (04/2012)
[article]
Titre : Separation of sunscreens in skincare creams using greener high-temperature liquid chromatography and subcritical water chromatography Type de document : texte imprimé Auteurs : B. Kapalavavi, Auteur ; R. Marple, Auteur ; C. J. Gamsky, Auteur ; Y. Yang, Auteur Année de publication : 2012 Article en page(s) : p. 169-175 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Chromatographie
Chromatographie en phase liquide à hautes performances
Peau -- Soins et hygiène
Produits antisolaires
Séparation (technologie)Tags : Avobenzone Ensulizole 'Chromatographie verte' liquide haute température' Homosalate Octinoxate Octisalate Octocrylène Oxybenzone 'Procter Gamble' 'Crème soin' chromatographie eau sous-critique; les filtres solaires; XBridge C18; XTerra MS ZirChrom-DiamondBond-C18 Index. décimale : 668.5 Parfums et cosmétiques Résumé : In this study, high-temperature liquid chromatographic (HTLC) and subcritical water chromatographic (SBWC) separations of sunscreens contained in skincare creams were achieved at temperatures ranging from 90 to 250°C. The columns employed in this work include a ZirChrom-DiamondBond-C18, a XTerra MS C18 and a XBridge C18 column. The quantity of methanol consumed by the greener HTLC sunscreen methods developed in this project is significantly reduced although the HTLC separation at this stage is not as efficient as that achieved by traditional HPLC. SBWC separation of sunscreens was also achieved on the XTerra MS C18 and the XBridge C18 columns using pure water at 230–250°C. Methanol was eliminated in the SBWC methods developed in this study. Note de contenu : - MATERIALS AND METHODS : reagents and materials - Preparation of standard solutions - Preparation of sample solutions - Instrumentation
- RESULTS AND DISCUSSION : ZirChrom-DiamondBond-C18 column - Waters XTerra MS C18 column - Waters XBridge C18 columnDOI : 10.1111/j.1468-2494.2011.00697.x En ligne : https://onlinelibrary.wiley.com/doi/10.1111/j.1468-2494.2011.00697.x Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=14388
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 34, N° 2 (04/2012) . - p. 169-175[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 13819 - Périodique Bibliothèque principale Documentaires Disponible Studies on the stability of preservatives under subcritical water conditions / B. Kapalavavi in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, Vol. 37, N° 3 (06/2015)
[article]
Titre : Studies on the stability of preservatives under subcritical water conditions Type de document : texte imprimé Auteurs : B. Kapalavavi, Auteur ; R. Marple, Auteur ; C. Gamsky, Auteur ; Yu Yang, Auteur Année de publication : 2015 Article en page(s) : p. 306-311 Note générale : Bibliogr. Langues : Anglais (eng) Catégories : Alcool benzylique L'alcool benzylique est un alcool de formule brute C6H5CH2OH. C'est un liquide incolore, inflammable et irritant.
Chromatographie à l'eau subcritique
Chromatographie en phase liquide à hautes performances
Conservateurs (chimie) -- analyse
Conservateurs (chimie) -- détérioration
Cosmétiques
Cosmétiques -- Additifs
Parabènes
Peau -- Soins et hygièneIndex. décimale : 668.5 Parfums et cosmétiques Résumé : - OBJECTIF : Le but de ce travail est de valider davantage les méthodes de chromatographies d'eau sous-critique (SBWC) pour la séparation et l'analyse des conservateurs, par l'évaluation de la stabilité de l'analyse dans l'eau sous-critique.
- METHODES : Dans cette étude, la dégradation des agents de conservation a été étudiée à des températures de 100 à 200°C en utilisant deux approches différentes. Premièrement, les surfaces des pics obtenus par SBWC à des températures élevées ont été comparées avec celles obtenues en utilisant la HPLC traditionnelle à 25°C. Dans la seconde approche, plusieurs agents de conservation et de l'eau ont été chargés dans une cuve et chauffés à des températures élevées pendant 30 ou 60 min. Les mélanges chauffés ont ensuite été analysés par GC/MS pour déterminer la stabilité de conservation.
- RESULTATS : Les tests t et F sur les résultats de la première méthode montrent que les surfaces des pics obtenus par HPLC et SBWC ne sont pas significativement différentes au seuil de confiance de 95%, ce qui signifie que les agents conservateurs étudiés sont stables pendant l'exécution de la SBWC à haute température. Bien que les résultats de la seconde approche montrent environ 10% de dégradation des conservateurs vers principalement de l'acide p-hydroxybenzoïque et de phénol à 200°C, les conservateurs étudiés sont stables entre 100 et 150°C. Ceci est en bon accord avec les résultats de la validation obtenus par la première méthode.
- CONCLUSION : Les résultats de ces travaux confirment que les méthodes de chromatographie de l'eau subcritique à des températures allant jusqu'à 150°C sont fiables pour la séparation et l'analyse des conservateurs dans les cosmétiques et d'autres échantillons.Note de contenu : - MATERIALS AND METHODS : Reagents and materials - Preparation of internal standard solutions - Preparation of standard solutions - Heating of water-multipreservatives or water-single paraben mixtures - SBWC and HPLC analysis - GC/MS analysis
- RESULTS : Chromatographic evaluation of preservatives stability under SBWC conditions - Non-chromatographic evaluation of preservatives stability under subcritical water conditions - Degradation products of parabens at 200°CDOI : 10.1111/ics.12200 Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=24080
in INTERNATIONAL JOURNAL OF COSMETIC SCIENCE > Vol. 37, N° 3 (06/2015) . - p. 306-311[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 17217 - Périodique Bibliothèque principale Documentaires Disponible