Corrosion resistance of HF-treated Mg alloy stent following balloon expansion and its improvement through biodegradable polymer coating / Xu Wei in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, Vol. 17, N° 4 (07/2020)
[article]
Titre : Corrosion resistance of HF-treated Mg alloy stent following balloon expansion and its improvement through biodegradable polymer coating Type de document : texte imprimé Auteurs : Xu Wei, Auteur ; Kensuke Sato, Auteur ; Yuki Koga, Auteur ; Makoto Sasaki, Auteur ; Takuro Niidoma, Auteur Année de publication : 2020 Article en page(s) : p. 1023-1032 Note générale : Bibliogr. Langues : Américain (ame) Catégories : Acide hydrofluorique
Anticorrosion
Caractérisation
Cellules -- Adhésivité
Implants médicaux
Implants résorbables
Magnésium -- Alliages
Polylactique, AcideL'acide polylactique (anglais : polylactic acid, abrégé en PLA) est un polymère entièrement biodégradable utilisé dans l'alimentation pour l'emballage des œufs et plus récemment pour remplacer les sacs et cabas en plastiques jusqu'ici distribués dans les commerces. Il est utilisé également en chirurgie où les sutures sont réalisées avec des polymères biodégradables qui sont décomposés par réaction avec l’eau ou sous l’action d’enzymes. Il est également utilisé pour les nouveaux essais de stent biodégradable.
Le PLA peut-être obtenu à partir d'amidon de maïs, ce qui en fait la première alternative naturelle au polyéthylène (le terme de bioplastique est utilisé). En effet, l'acide polylactique est un produit résultant de la fermentation des sucres ou de l'amidon sous l'effet de bactéries synthétisant l'acide lactique. Dans un second temps, l'acide lactique est polymérisé par un nouveau procédé de fermentation, pour devenir de l'acide polylactique.
Ce procédé conduit à des polymères avec des masses molaires relativement basses. Afin de produire un acide polylactique avec des masses molaires plus élevées, l'acide polylactique produit par condensation de l'acide lactique est dépolymérisé, produisant du lactide, qui est à son tour polymérisé par ouverture de cycle.
Le PLA est donc l’un de ces polymères, dans lequel les longues molécules filiformes sont construites par la réaction d’un groupement acide et d’une molécule d’acide lactique sur le groupement hydroxyle d’une autre pour donner une jonction ester. Dans le corps, la réaction se fait en sens inverse et l’acide lactique ainsi libéré est incorporé dans le processus métabolique normal. On obtient un polymère plus résistant en utilisant l'acide glycolique, soit seul, soit combiné à l’acide lactique.
Revêtements organiquesIndex. décimale : 667.9 Revêtements et enduits Résumé : Magnesium (Mg) alloy has been actively investigated as a bioresorbable scaffold (BRS) for use as a next-generation stent because of its appropriate mechanical properties and biocompatibility. However, Mg alloy quickly degrades in the physiological environment. Hydrofluoric acid (HF) treatment and surface coating with biodegradable polymer are approaches for enhancing the corrosion resistance of Mg alloy. However, there are no studies that focus on the corrosion behavior of the Mg alloy stent after balloon catheter expansion, which results in mechanical stress and is required for stent placement. In this study, the corrosion behavior of a Mg alloy stent after expansion by a balloon catheter was investigated. Compared with the bare Mg alloy stent, the HF-treated Mg alloy stent showed excellent corrosion resistance without expansion. However, balloon catheter expansion caused small fragments and cracks to appear on the surface of the HF-treated Mg alloy stent and accelerated its corrosion rate. The HF-treated Mg alloy stent was therefore further coated with poly(d,l-lactic acid) (PDLLA). As a result, the high corrosion resistance of the coated stent was maintained after its expansion along with higher biocompatibility for endothelial cell adhesion than the stent without the polymer coating. The HF-treated and PDLLA-coated platform is expected to be a BRS candidate for clinical applications. Note de contenu : - EXPERIMENTAL : Materials - Stent HF treatment and biodegradable polymer coating - Surface - Characterization - Contraction and expansion of the stent - Evaluation of corrosion - Cell adhesion
- RESULTS AND DISCUSSION : Physicochemical characteristics of HF-treated Mg alloy stents - Corrosion behavior of the HF-treated Mf alloy stents with and without expansion - Polymer coating of HF-treated Mf alloy stents - HUVEC adhesion on the PDLLA-coated Mg alloyDOI : https://doi.org/10.1007/s11998-019-00284-5 En ligne : https://link.springer.com/content/pdf/10.1007/s11998-019-00284-5.pdf Format de la ressource électronique : Permalink : https://e-campus.itech.fr/pmb/opac_css/index.php?lvl=notice_display&id=34389
in JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH > Vol. 17, N° 4 (07/2020) . - p. 1023-1032[article]Réservation
Réserver ce document
Exemplaires (1)
Code-barres Cote Support Localisation Section Disponibilité 21864 - Périodique Bibliothèque principale Documentaires Disponible